Re: Testing ECL84/6GW8 on Hickok 752A

by François Yves Le Gal <flegal@[EMAIL PROTECTED] > May 8, 2008 at 07:38 PM

On Thu, 8 May 2008 14:20:42 +0100, tooshy <tooshy.268d18a@[EMAIL PROTECTED]
>
wrote:
>Can anybody provide me with the settings to test a ECL84/6GW8 on the
>Hickok 752A?

On a 539:

Pentode Section
Selections EV-8637-1
Bias 1.0V
Press P4
Range C
Min Mutual Conductance 5500

Triode Section
Selections EV-1902-0
Bias 0.7V
Press P4
Range E
Min Mutual Conductance 550
 