valhealey wrote:
> Tim Schwartz wrote:
>> RuF wrote:
>>> Hi Experts,
>>>
>>> I have finally managed to get my 1219 going again, this time with a
>>> new Shure M97xE.
>>> It feeds into a Sony STRAV260 amplifier via RCA cables.
>>>
>>> The right channel is working fine but the left one has a very weak
>>> output. I swapped the
>>> RCA connectors at the amplifier and output behavior also swapped, so
>>> the problem is at the turntable.
>>>
>>> Under the turntable there are four connector prongs beside the muting
>>> switch. Two of the connectors are between one and two inches above
>>> the others. The pair closest to the axis of the turntable are
>>> attached to ends of the RCA cables. One of the other prongs has
>>> nothing connected and the fourth prong is connected to a ground lead
>>> that goes to the amplifier case and to the ****elds of the two wires
>>> that carry the output from the cartridge.
>>>
>>> Without taking the arm off, it's not easy to see into that area under
>>> the shell. Is it likely that there is a bad contact there?
>>>
>>> Comments appreciated.
>>>
>>> RuF
>>
>> RuF,
>>
>> It is possible that the muting switch is causing the problem, but
>> not the first thing I'd suspect.
>>
>> Dual used among the worst RCA cables in existence, so if you have not
>> already tried new ones, I would. The factory ones used crimped
>> connections, and the grounds commonly go bad causing hum and bad
>> connections.
>>
>> There is a similar problem with the head shell leads These can be
>> resoldered, but you have to be VERY careful not to damage the head
>> shell contacts. Both the cartridge and head shell ends of the 4 wires
>> are suspect. You might want to consider a new head shell if they are
>> still available. A new old stock head shell may have the same
>> problems as your existing one, as the crimps have been around for many
>> years.
>>
>> The contacts in the arm itself, where the head shell connects can
>> often be corroded. Don't use a rough abrasive, as you'll remove the
>> plating. I'd start with a cotton swab moistened (not dripping) with a
>> contact cleaner. Do the head shell side of things too. I would then
>> use a dry q-tip to remove as much of the cleaner as possible. To be
>> really residue free, you could clean with alcohol.
>>
>> Of course, first start by being sure that the head shell leads are all
>> going to the right places, and make sure the lugs going onto the
>> cartridge pins are snug. If they are loose, squeeze them GENTLY with
>> needle nose pliers or tweezers to tighten them up a bit. Be careful,
>> if you over-tighten them, then they won't fit the pins on the
>> cartridge any more. They can also break.
>>
>> Lastly, are you sure that the new cartridge is good? If you have an
>> ohmmeter, then measure the left and right windings of the cartridge.
>> The readings should be similar. This needs to be done with the head
>> shell removed from the turntable, but the cartridge can still be
>> mounted in the head shell.
>>
>> Regards,
>> Tim Schwartz
>> Bristol Electronics
>
> Thanks Tim.
>
> As you suggested I cleaned up all the contacts near the pickup and then
> reinstalled
> but it didn't do any good. Next I tweaked the contacts at the rear of
> the shell and reinstalled.
> That did the trick. Thanks again for your help.
>
> RuF.
Seems like I spoke too soon. After copying 4 records to the
HD, the right channel
has now become the very weak one and the left is ok. I have
tried several different
records to make sure they were stereo and they were. I
tweaked the R and RG contacts
at the rear of the shell but that was no help.
I made some measurements across the 2 RCA connectors and
there was symmetry in
the resistances. For example, across the two skirts the
resistance was 0. From the black
prong to the red prong the resistance was 2.8 ohms. From the
black prong to the red skirt
and from the red prong to the black skirt the resistance was
1.35 ohms.
Comments appreciated


|